Alarm Systems and Devices I

MMP

Quizzes

Alarm Systems and Devices I

These quizzes have been designed to assist individuals in becoming a well rounded Fire and Life Safety Director.  Croker’s quiz training module may be used in conjunction with Croker’s FDNY accredited course (and distributed course material) to aid in the learning process.

How to use this quiz training module:

Press the Get Started button below to begin.  After selecting an answer, click the Next Question button to see if your answer is correct (green) or incorrect (red).

If correct, click Next Question again to proceed to the next slide.  If incorrect, you may continue to try until you get the correct answer before moving on to the Next Question.

1 / 23

Question 1.

All fire alarm pull stations must be painted red, and must be securely mounted to the wall at what distance above the floor level?

2 / 23

Question 2.

Supervisory devices provide signals which indicate that a system or device being monitored is in an abnormal state. All of the following will send a supervisory signal to the Fire Command Center EXCEPT?

3 / 23

Question 3.

There are occasions when a Fire and Life Safety Director (FLSD) has to put the building’s fire alarm system off-line. In which of the following scenarios would the FLSD be LEAST LIKELY to do so?

4 / 23

Question 4.

How many kinds of fire alarm pull stations are there?

5 / 23

Question 5.

Specific entries must be made in an Alarm Logbook when an Alarm is activated. Each of following choices represents a required entry, EXCEPT:

6 / 23

Question 6.

Which one of the following signals is initiated by the fire alarm system and indicates that there is a fault in a monitored circuit or component?

7 / 23

Question 7.

Which statement is correct if a security company wants to install a hidden camera in a fake smoke detector?

8 / 23

Question 8.

An alarm transmitted to the Fire Department for which the detector system functioned for other than its intended purpose. Causes may be: lack of maintenance, improper detector placement, improper system installation, induced electrical currents, improper detector setting for installed location, computer console malfunction, etc. This type of alarm is called …

9 / 23

Question 9.

Which term best describes an engineered system that uses mechanical fans to produce pressure differences across smoke barriers or that establishes airflow to limit smoke movement?

10 / 23

Question 10.

All of the following are correct statements regarding the Alarm Logbook EXCEPT?

11 / 23

Question 11.

What is the maximum number of unwarranted/unnecessary alarms ALLOWED by the FDNY in any three (3) month period BEFORE the FDNY will issue a summons to the building?

12 / 23

Question 12.

If/when the audible fire alarm on the 15th floor is unable to function in conformance with the law, whom should the Fire and Life Safety Director (FLSD) notify?

13 / 23

Question 13.

In a certain type of smoke detector, a light source and a photosensitive sensor are so arranged that the rays from the light source do not normally fall on the photosensitive sensor. When smoke particles enter the light path, some of the light is scattered by reflection and refraction onto the sensor, causing the detector to respond. What is the names of this type of smoke detector?

14 / 23

Question 14.

An ionization smoke detector contains a material which ionizes the air in the sensing chamber, thus rendering it conductive and permitting a current to flow between two charged electrodes. When the conductance is less than a predetermined level, the detector responds. What material ionizes the air in the sensing chamber?

15 / 23

Question 15.

During a fire emergency, who must control the post fire smoke systems?

16 / 23

Question 16.

Which of the following items is REQUIRED to be kept at the Fire Command Center during business hours?

17 / 23

Question 17.

The cover of the logbook shall bear the inscription, “ALARM LOGBOOK”, as well as the name and address of the building. All entries shall be made in ink and dated. A separate logbook shall be kept for each calendar year. How long after the date of the last entry must the logbooks be retained?

18 / 23

Question 18.

Which of the following is a characteristic of a fixed-temperature heat detector?

19 / 23

Question 19.

Where on the premises should the Alarm Logbook be kept?

20 / 23

Question 20.

Which one of the following signals indicates that a system or device being monitored is in an abnormal state?

21 / 23

Question 21.

It shall be unlawful to transmit unnecessary or unwarranted alarms in any three-month period if the amount of those alarms is:

22 / 23

Question 22.

In an office building, how frequently shall the name and the Certificate of Fitness number of the Fire and Life Safety Director (FLSD) on duty, and the time each tour of duty began and ended, be entered in the Alarm Logbook?

23 / 23

Question 23.

Any premises which has a defined fire alarm system, must also maintain, on the premises, an Alarm Logbook. Which statement is NOT accurate regarding the alarm logbook?

Your score is

The average score is 0%

0%