Skip to content Skip to footer

Suppression Systems I

MMP

Quizzes

Suppression Systems I

These quizzes have been designed to assist individuals in becoming a well rounded Fire and Life Safety Director.  Croker’s quiz training module may be used in conjunction with Croker’s FDNY accredited course (and distributed course material) to aid in the learning process.

How to use this quiz training module:

Press the Get Started button below to begin.  After selecting an answer, click the Next Question button to see if your answer is correct (green) or incorrect (red).

If correct, click Next Question again to proceed to the next slide.  If incorrect, you may continue to try until you get the correct answer before moving on to the Next Question.

1 / 20

Question 1.

Which of the following will indicate that the main water control valve on a standpipe system is open?

2 / 20

Question 2.

In a Dry Pipe Sprinkler Systems a dry pipe valve is installed where the water supply enters the sprinkler system. Piping in the sprinkler system is filled with air under pressure, and water is prevented from entering the piping by the dry pipe valve. The air pressure in the piping keeps the valve in the closed position. When a sprinkler head opens, the valve opens because …

3 / 20

Question 3.

The Certificate of Fitness holder shall maintain a detailed record of all sprinkler head inspections. A record card with the date of each inspection, the Certificate of Fitness number, and the signature of the Certificate of Fitness holder shall be posted …

4 / 20

Question 4.

What color is the entire Fire Department Connection (Siamese Connection) of a non-automatic sprinkler system?

5 / 20

Question 5.

A supply of at least six (6) extra appropriate sprinkler heads must be kept available on the premises. Where must these extra sprinkler heads be stored?

6 / 20

Question 6.

The manufacturer may have painted part of the sprinkler head. If any other paint gets on the sprinkler head, or if foreign material has accumulated on it, it must be …

7 / 20

Question 7.

What color are the caps of each Fire Department Connection (Siamese Connection) used for combination standpipe and sprinkler systems to be painted?

8 / 20

Question 8.

OS&Y gate valves are installed at several places in the standpipe system. The OS&Y valves can be used to shut down part of the standpipe system. Sections may be shut down for testing, repairs or maintenance. In what position must the stem of an OS&Y valve be kept in at all times?

9 / 20

Question 9.

A roof manifold is used for:

10 / 20

Question 10.

What is the diameter of the fire hoses in Class I standpipe systems?

11 / 20

Question 11.

A sprinkler head rated “ordinary” will operate at what temperature range?

12 / 20

Question 12.

Each standpipe system is fitted with a drain valve. The drain valve is located at the lowest point on the standpipe system. The drain valve is used when the standpipe system is being tested or repaired. In what position is the drain valve of a standpipe system sealed under normal conditions?

13 / 20

Question 13.

With regard to sprinkler heads, all of the following are correct EXCEPT?

14 / 20

Question 14.

Which statement is true about a multi-zone standpipe system?

15 / 20

Question 15.

Which of the following is a component of the standpipe system?

16 / 20

Question 16.

Normally, the pipes in a non-automatic sprinkler systems are dry. In non-automatic sprinkler systems, water is supplied when necessary by pumping water into the system through the:

17 / 20

Question 17.

Where Fire Department Connections (Siamese Connections) are installed, metal signs shall be fastened to (or above) the connection indicating the area protected. What color must the caps of each automatic sprinkler Fire Department Connection be painted?

18 / 20

Question 18.

In Automatic Dry Pipe Sprinkler Systems a dry pipe valve is installed where the water supply enters the sprinkler system. Piping in the sprinkler system is filled with air under pressure, and water is prevented from entering the piping by the dry pipe valve. The air pressure in the piping keeps the valve in the closed position. When a sprinkler head opens, the valve opens because …

19 / 20

Question 19.

Which statement is INCORRECT with regard to the exposed piping and control valve handles of the fire protection systems?

20 / 20

Question 20.

A Wet Standpipe system always has water under pressure in the piping so it should be protected from freezing. In some cases it may be necessary to increase the water pressure by means of a …